Elektrische Modulkenngrößen
Nennwerte bei Standard Testbedingungen (StC: 1000 W/m², 25˚C, am 1,5 Spektrum)
Nennleistung (+5/-0 Wp) | PMAX [W] | 90,0 |
Kurzschlussstrom | ISC [A] | 1,67 |
Leerlaufspannung | UOC [V] | 76,5 |
Strom bei max. Leistung | IMPP [A] | 1,48 |
Spannung bei max. Leistung | UMPP [V] | 60,8 |
Modulwirkungsgrad | η [%] | ≥12,0 |
Die realen Messwerte werden bei der Auslieferung pro Modul zur Verfügung gestellt.
Anlage
97 St. Q.SMART 90 UF ergeben eine Anlagenleistung von max. 4,41 kWp
Mithilfe des PV potential estimation utility lässt sich der zu erwartende Ertrag ausrechenen.
PVGIS estimates of solar electricity generation
Location: 51°33'1" North, 12°8'13" East, Elevation: 97 m a.s.l.,
Solar radiation database used: PVGIS-classic
Nominal power of the PV system: 4.4 kW (CIS)
Estimated losses due to temperature: 6.3% (using local ambient temperature)
Estimated loss due to angular reflectance effects: 3.3%
Other losses (cables, inverter etc.): 10.0%
Combined PV system losses: 18.5%
Ed: Average daily electricity production from the given system (kWh)
Em: Average monthly electricity production from the given system (kWh)
Hd: Average daily sum of global irradiation per square meter received by the modules of the given system (kWh/m2)
Hm: Average sum of global irradiation per square meter received by the modules of the given system (kWh/m2)
PVGIS © European Communities, 2001-2010
Reproduction is authorised, provided the source is acknowledged
Location: 51°33'1" North, 12°8'13" East, Elevation: 97 m a.s.l.,
Solar radiation database used: PVGIS-classic
Nominal power of the PV system: 4.4 kW (CIS)
Estimated losses due to temperature: 6.3% (using local ambient temperature)
Estimated loss due to angular reflectance effects: 3.3%
Other losses (cables, inverter etc.): 10.0%
Combined PV system losses: 18.5%
Fixed system: inclination = 22°, orientation = -10° | ||||
Month | Ed | Em | Hd | Hm |
---|---|---|---|---|
Jan | 3.94 | 122 | 1.02 | 31.8 |
Feb | 6.85 | 192 | 1.80 | 50.4 |
Mar | 10.00 | 311 | 2.68 | 82.9 |
Apr | 14.10 | 424 | 3.89 | 117 |
May | 17.50 | 542 | 4.93 | 153 |
Jun | 16.50 | 495 | 4.73 | 142 |
Jul | 17.40 | 541 | 5.03 | 156 |
Aug | 15.50 | 479 | 4.44 | 138 |
Sep | 11.70 | 350 | 3.27 | 98.0 |
Oct | 8.21 | 254 | 2.24 | 69.4 |
Nov | 4.39 | 132 | 1.17 | 35.0 |
Dec | 2.69 | 83.3 | 0.70 | 21.8 |
Yearly average | 10.8 | 327 | 3.00 | 91.2 |
Total for year | 3920 | 1090 |
Ed: Average daily electricity production from the given system (kWh)
Em: Average monthly electricity production from the given system (kWh)
Hd: Average daily sum of global irradiation per square meter received by the modules of the given system (kWh/m2)
Hm: Average sum of global irradiation per square meter received by the modules of the given system (kWh/m2)
PVGIS © European Communities, 2001-2010
Reproduction is authorised, provided the source is acknowledged
Diese Werte sind sehr konservativ gerechnet aufgrund des "anderen Verlustes" von 10%.